Automated Weather Station (Weather Monitoring unit)
Sensor Specifications
Air Temperature & Relative Humidity
Air Temperature

- Range: 40 C to 60 C
- Resolution: 0.01
- Response Time( @ 63% ): < 10 secs
- Accuracy:0.1 C
- Type:RTD (pt100)
- Calibrated by :lMD
Relative Humidity
- Range: 0 to 100%
- Resolution: 0.2
- Response Time( @ 63% ): < 10 secs
- Accuracy:0.8 %
- Type:Capacitive
- Calibrated by :lMD
**Specification meets:
"World Meteorological Organization"(WMO) Standards
Atmospheric Pressure

- Range: 500 to 1100 mb
- Resolution: 0.01
- Response Time: < 10 secs
- Accuracy:0.1 mb
- Type: Resonant
- Calibrated by : lMD
**Specification meets:
"World Meteorological Organization"(WMO) Standards
Wind Speed & Wind Direction
Wind speed

- Range : 0 to 60 m/s(0 to 250 kmph)
- Resolution : 0.01
- Response Time : < 10 secs
- Accuracy:0.02 m/s (0.72 kmph)
- Type: Ultrasonic
- Calibrated by : lMD
Wind Direction
- Range : 0 to 360 degrees
- Resolution : 1
- Response Time : < 10 secs
- Accuracy:3
- Type: Ultrasonic
- Calibrated by : lMD
**Specification meets:
"World Meteorological Organization"(WMO) Standards
Solar Radiation:

- Range : 10 to 1750 W/m2
- Resolution : 1 Watt
- Response Time : < 10 secs
- Accuracy : 5%
- Sensitivity : 5 W/m2
- Spectral range : 300 to 1000 nm
- Type: Pyranometer (Silicon photodiode)
Soil Temperature:

- Range : -40 C to 60 C
- Resolution : 0.01
- Response Time( @ 63% ) : < 10 secs
- Accuracy : 0.1 C
- Type : RTD (pt100)
- Calibrated by : Internal calibration(Reference calibration)
Soil Moisture:

- Range : 0 to 100%
- Resolution : 1
- Response Time : < 10 secs
- Accuracy : 2%
- Type : Time Domain Reflectometer(TDR)
- Calibrated by : Internal calibration(gravimetric method)